Suite v1.0.0 · Dataset release v1.1.0

2D Nesting Benchmark Suite

Explore five published nesting layouts for plate, sheet and irregular remnant stock. Review geometric utilization, every placed and unplaced part, and the recorded native Rust timings against fixed public inputs.

5 validated casesNative Rust referenceData-only downloadsCC BY 4.0

Reference overview

5 fixed cases

Exact fit, steel plate, wood sheet, an irregular remnant with a void, and exhausted finite stock.

5 of 5 validated

Part counts, polygon areas, stock inventory, rotations, gaps and edge margins are checked against the original inputs.

30 runs per case

Three warmups followed by 30 measured native solver calls. Every raw duration is included in the JSON.

Geometric utilization

Part polygon area divided by used stock polygon area. Stock holes are subtracted from the available area.

Published native Rust reference results

Recorded 2026-07-22 on win32 10.0.22000, Intel(R) Core(TM) i5-9400F CPU @ 2.90GHz, 6 logical cores and 31.932 GiB memory. The run used rustc 1.96.1 (31fca3adb 2026-06-26) and Node v26.4.0.

p50 and p95 cover synchronous native solver calls. Parsing, validation, browser initialization, workers and UI are excluded. These timings describe this engine version and machine; they are separate from the 1D Node/WASM reference and from browser performance.

All five native Rust benchmark cases; areas in square metres and solve times in milliseconds.
Case / layoutStatusSheetsPlacedUnplacedStock m²Parts m²UtilizationUnused areap50 msp95 ms
Exact square gridCompleted14011100%0%0.5650.683
Steel plate panel gridCompleted11204.54.204893.44%6.56%7.9448.419
Wood sheet panel gridCompleted11202.97682.8896.748%3.252%7.6528.054
Irregular remnant with a voidCompleted1400.00630.001625.397%74.603%7.8638.431
Finite sheet stock exhaustedCompleted1120.010.003636%64%0.5170.559

Areas above are shown in m²; the source JSON and CSV use mm². The stock-exhausted case intentionally leaves two parts unplaced. The irregular-remnant case tests concavity and void avoidance; its utilization is specific to that geometry.

Inspect each layout and its constraints

These previews use the polygon coordinates from the original result. Part outlines are visual separators; their line width does not represent kerf. Grey is unused stock, teal is placed parts, and stock voids are unfilled.

exact

Exact square grid

Four equal square parts exactly cover one square sheet with zero gap and edge margin, providing a minimal area-accounting fixture.

Square panel · square-panel-1 · 0°Square panel · square-panel-2 · 0°Square panel · square-panel-3 · 0°Square panel · square-panel-4 · 0°
1000 x 1000 sheet · 1,000 × 1,000 mm · 1,000,000 mm² stock area
Placed / requested
4 / 4
Geometric utilization
100%
Part gap
0 mm
Edge margin
0 mm
Allowed rotations
0° / 90°
Deterministic seed
2026072201

steel

Steel plate panel grid

Twelve repeated steel panels are nested on one 3000 by 1500 millimetre plate with a 10 millimetre part gap and edge margin.

Steel panel 730 x 480 · steel-panel-730x480-1 · 0°Steel panel 730 x 480 · steel-panel-730x480-2 · 0°Steel panel 730 x 480 · steel-panel-730x480-3 · 0°Steel panel 730 x 480 · steel-panel-730x480-4 · 0°Steel panel 730 x 480 · steel-panel-730x480-5 · 0°Steel panel 730 x 480 · steel-panel-730x480-6 · 0°Steel panel 730 x 480 · steel-panel-730x480-7 · 0°Steel panel 730 x 480 · steel-panel-730x480-8 · 0°Steel panel 730 x 480 · steel-panel-730x480-9 · 0°Steel panel 730 x 480 · steel-panel-730x480-10 · 0°Steel panel 730 x 480 · steel-panel-730x480-11 · 0°Steel panel 730 x 480 · steel-panel-730x480-12 · 0°
S275 plate 3000 x 1500 x 6 · 3,000 × 1,500 mm · 4,500,000 mm² stock area
Placed / requested
12 / 12
Geometric utilization
93.44%
Part gap
10 mm
Edge margin
10 mm
Allowed rotations
0° / 90°
Deterministic seed
2026072202

wood

Wood sheet panel grid

Twelve cabinet-sized panels are nested on one 2440 by 1220 millimetre sheet with a 5 millimetre tool gap and edge margin.

Cabinet panel 600 x 400 · wood-panel-600x400-1 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-2 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-3 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-4 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-5 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-6 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-7 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-8 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-9 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-10 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-11 · 0°Cabinet panel 600 x 400 · wood-panel-600x400-12 · 0°
Birch plywood 2440 x 1220 x 18 · 2,440 × 1,220 mm · 2,976,800 mm² stock area
Placed / requested
12 / 12
Geometric utilization
96.748%
Part gap
5 mm
Edge margin
5 mm
Allowed rotations
0° / 90°
Deterministic seed
2026072203

irregular remnant

Irregular remnant with a void

Four square tiles must fit inside a concave L-shaped reusable remnant while avoiding an internal stock void and preserving edge margin.

Tile · tile-1 · 0°Tile · tile-2 · 0°Tile · tile-3 · 0°Tile · tile-4 · 0°
L remnant · 100 × 100 mm · 6,300 mm² stock area after subtracting the void
Placed / requested
4 / 4
Geometric utilization
25.397%
Part gap
2 mm
Edge margin
1 mm
Allowed rotations
0° / 90°
Deterministic seed
2026072204

failure boundary

Finite sheet stock exhausted

Three large panels compete for one finite sheet that can hold only one, requiring two explicit stock-exhausted results.

Large panel · large-panel-1 · 0°
Single 100 x 100 plate · 100 × 100 mm · 10,000 mm² stock area
Placed / requested
1 / 3
Geometric utilization
36%
Part gap
2 mm
Edge margin
0 mm
Allowed rotations
0° / 90°
Deterministic seed
2026072205

2 requested parts unplaced. The available compatible stock was exhausted. Their IDs and reasons are retained in the result JSON.

Measurement and validation

The existing reference run used the production optimize_nest entry point through its native Rust adapter. All 150 measured calls retain their raw times. The original report records clean engine and dataset worktrees and successful solver invariants.

This publication independently rechecks all five stored layouts: each requested part appears once as placed or unplaced, inventory limits hold, part shapes and rotations match their definitions, and geometry respects stock boundaries, voids, part gaps and edge margins. Areas, timing percentiles and CSV rows are reconstructed from the published data.

Used stock polygon area = placed part polygon area + estimated unused area.

Read the complete methodology
Open the 2D workspace Inspect the 1D cutting resultsBrowse files and templates

Feedback & support

Hi! Share a problem, an idea, or a question about CutNesting. I’ll save your message for the team.

What would you like to share?

Up to 4,000 characters

Your message, optional email and this page’s path are saved for support. Privacy details